Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
PLoS One ; 16(11): e0260140, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34793558

RESUMEN

INTRODUCTION: Early endotracheal intubation improves neurological outcomes in cardiopulmonary resuscitation, although cardiopulmonary resuscitation is initially carried out by personnel with limited experience in a significant proportion of cases. Videolaryngoscopes might decrease the number of attempts and time needed, especially among novices. We sought to compare videolaryngoscopes with direct laryngoscopes in simulated cardiopulmonary resuscitation scenarios. MATERIALS AND METHODS: Forty-four medical students were recruited to serve as novice users. Following brief, standardized training, students executed endotracheal intubation with the King Vision®, Macintosh and VividTrac® laryngoscopes, on a cardiopulmonary resuscitation trainer in normal and difficult airway scenarios. We evaluated the time to and proportion of successful intubation, the best view of the glottis, esophageal intubation, dental trauma and user satisfaction. RESULTS: In the normal airway scenario, significantly shorter intubation times were achieved using the King Vision® than the Macintosh laryngoscope. In the difficult airway scenario, we found that the VividTrac® was superior to the King Vision® and Macintosh laryngoscopes in the laryngoscopy time. In both scenarios, we noted no difference in the first-attempt success rate, but the best view of the glottis and dental trauma, esophageal intubation and bougie use were more frequent with the Macintosh laryngoscope than with the videolaryngoscopes. The shortest tube insertion times were achieved using the King Vision® in both scenarios. CONCLUSION: All providers achieved successful intubation within three attempts, but we found no device superior in any of our scenarios regarding the first-attempt success rate. The King Vision® was superior to the Macintosh laryngoscope in the intubation time in the normal airway scenario and noninferior in the difficult airway scenario for novice users. We noted significantly less esophageal intubation using the videolaryngoscopes than using the Macintosh laryngoscope in both scenarios. Based on our results, the KingVision® might be recommended over the VividTrac® and Macintosh laryngoscopes for further evaluation.


Asunto(s)
Reanimación Cardiopulmonar/métodos , Educación Médica/métodos , Laringoscopía/métodos , Adulto , Femenino , Humanos , Intubación Intratraqueal/métodos , Laringoscopios , Masculino , Estándares de Referencia , Fenómenos Fisiológicos Respiratorios , Sistema Respiratorio/anatomía & histología , Estudiantes de Medicina , Encuestas y Cuestionarios , Adulto Joven
2.
J Water Health ; 16(4): 635-645, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30067244

RESUMEN

Exposure to various endocrine disrupting chemicals (EDCs) can lead to adverse effects on reproductive physiology and behavior in both animals and humans. An adequate strategy for the prevention of environmental contamination and eliminating the effects of them must be established. Chemicals with estrogenic activity were selected, and the effectiveness of their removal during the purification processes in two drinking water treatment plants (DWTPs) using riverbank infiltrated water was determined. Thirty-five water samples in two sampling campaigns throughout different seasons were collected and screened with a yeast estrogen test; furthermore, bisphenol A (BPA), 17ß-estradiol (E2) and ethinyl-estradiol (EE2) content were measured using high-performance liquid chromatography-mass spectrometry (HPLC-MS). Our results confirm that estrogenic compounds are present in sewage effluents and raw surface river water of DWTPs. Very low estrogen activity and pg/L concentrations of BPA and E2 were detected during drinking water processing and occasionally in drinking water. Based on this study, applied riverbank filtration and water treatment procedures do not seem to be suitable for the total removal of estrogenic chemicals. Local contamination could play an important role in increasing the BPA content of the drinking water at the consumer endpoint.


Asunto(s)
Compuestos de Bencidrilo/farmacología , Disruptores Endocrinos/química , Estradiol/farmacología , Fenoles/farmacología , Ríos/química , Contaminantes Químicos del Agua/farmacología , Levaduras/efectos de los fármacos , Compuestos de Bencidrilo/química , Disruptores Endocrinos/farmacología , Estradiol/química , Fenoles/química , Contaminantes Químicos del Agua/química
3.
BMC Anesthesiol ; 17(1): 68, 2017 05 26.
Artículo en Inglés | MEDLINE | ID: mdl-28549421

RESUMEN

BACKGROUND: Direct laryngoscopy remains the gold standard for endotracheal intubation and is preferred by experienced operators. However, an increasing number of reports currently support videolaryngoscopy, particularly for novice users. The widespread use of videolaryngoscopy may be limited due to financial limitations, especially in low-income countries. Therefore, affordable single-use scopes are now becoming increasingly popular. We sought to compare these new scopes with direct laryngoscopes and the previously tested videolaryngoscopes in mannequins by novices. METHODS: Fifty medical students were recruited to serve as novice users. Following brief, standardized training, students were asked to execute endotracheal intubation with each of the devices, including the Airtraq®, a custom-made videolaryngoscope, the King Vision®, the Macintosh laryngoscope and the VividTrac®, on an airway trainer (Laerdal Airway Management Trainer®) in normal and difficult airway scenarios. We evaluated the time to and the proportion of successful intubation, the best view of the glottis, esophageal intubation, dental trauma and user satisfaction. RESULTS: We observed no differences in esophageal intubation. However, intubation-related times, the view of the glottis and operator satisfaction were significantly better throughout the study with the commercial videolaryngoscopes. In comparison, the custom-made videolaryngoscope performance proved to be similar to that of the Macintosh laryngoscope. The VividTrac® performance was similar (P > 0.05) or significantly better than that of the King Vision® in both scenarios. CONCLUSIONS: Based upon our results, the Airtraq®, King Vision® and VividTrac® were superior to the Macintosh laryngscope in both normal and difficult airway scencarios for novice users. In particular, our study is the first to report that the VividTrac® shows promise for further clinical evaluation.


Asunto(s)
Laringoscopios , Maniquíes , Grabación en Video , Diseño de Equipo , Humanos , Intubación Intratraqueal , Laringoscopía , Entrenamiento Simulado , Estudiantes de Medicina , Factores de Tiempo
4.
Brain Res ; 1543: 159-64, 2014 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-24252621

RESUMEN

The mediodorsal prefrontal cortex (mdPFC), as part of the forebrain glucose-monitoring (GM) system, plays important role in several regulatory processes to control the internal state of the organism and to initiate behavioral outputs accordingly. Little is known, however, about the neurochemical sensitivity of neurons located in this area. Substantial evidence indicates that the locus ceruleus - noradrenaline (NA) projection system and the nucleus basalis magnocellularis - cholinergic projection system regulate behavioral state and state dependent processing of sensory information, various cognitive functions already associated with the mdPFC. The main goal of the present study was to examine noradrenergic and cholinergic responsiveness of glucose-monitoring and glucose-insensitive (GIS) neurons in the mediodorsal prefrontal cortex. One fifth of the neurons tested changed in firing rate to microelectrophoretically applied NA. Responsiveness of the GM cells to this catecholamine proved to be significantly higher than that of the GIS units. Microiontophoretic application of acetylcholine (Ach) resulted in activity changes (predominantly facilitation) of more than 40% of the mdPFC neurons. Proportion of Ach sensitive units among the GM and the GIS neurons was found to be similar. The glucose-monitoring neurons of the mdPFC and their distinct NA and remarkable Ach sensitivity are suggested to be of particular significance in prefrontal control of adaptive behaviors.


Asunto(s)
Acetilcolina/farmacología , Glucosa/metabolismo , Neuronas/efectos de los fármacos , Norepinefrina/farmacología , Corteza Prefrontal/citología , Animales , Biofisica , Relación Dosis-Respuesta a Droga , Interacciones Farmacológicas , Estimulación Eléctrica , Iontoforesis , Masculino , Potenciales de la Membrana/efectos de los fármacos , Ratas , Ratas Sprague-Dawley , Ratas Wistar
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...